Atlas70 (Single Phase)


View larger image

Price: £3,295.00 (£3,954.00 inc. VAT)
4010
4-5 working days
12 months

 
Description
Downloadable Documents
Related products

The Atlas70 (Single Phase) is a fully automatic floor mounted pumping station suitable for pumping both foul and storm water to a higher level when gravity drainage is not possible or economical to install.

The system is suitable for installing either at the initial building stage or retro fitting to existing buildings and can accept waste from a bathroom, changing room, commercial premises or similar.

The system consists of a polyethylene tank, control panel with a built in automatic vortex pump.

The Atlas70 (Single Phase) is easy to install, as there are a number of inlets at varying levels/sizes available (inlets to be cut onsite).

Dimensions

 Model
Length
Width
Height
Atlas70 (Single Phase)
800mm
500mm
423mm

 

Specification

Model
Atlas70 (Single Phase) 
Power Supply
230V AC
Rated Current
8.4A
Motor Rating
1300W
Frequency
50Hz
Revolutions per Minute
1450rpm
Max. Vertical Output
7m
Max. Horizontal Output
70m
Max. Flow Rate
750 l/m
Max. Liquid Temp.
<40°C
Discharge Size
80mm
Cable Length
4m
Weight
55kg
Colour
White

 

Installation guidelines

It is important to note that these instructions are for guidance only. Please refer to the full Installation and Operating Guidelines when specifying / installing the product.

Siting the product
The Atlas70 (Single Phase) should be positioned on a firm level surface, resistant to condensation. The unit must be located lower than the outflow of the appliances served so as to provide a gravity fall into the unit.

It is extremely important to site the Atlas70 (Single Phase) with access in mind in the event of maintenance being required.

Inlet connections
The Atlas70 (Single Phase) comes with a variety of pre-moulded inlets to accept incoming pipework ranging from 40mm to 100mm. To utilise the inlets you must open up the moulded inlet by sawing the end off, leaving enough of the mould to act as a support area for a push-on sleeve. The incoming pipework must then be pushed into the push on sleeve and fixed securely in place using an appropriate jubilee clip.

Discharge connection
The discharge line of the Atlas70 (Single Phase) should be 3” PVC Class E pressure pipe.

To connect to the discharge line an appropriately sized PN16 Gate valve (not supplied, see accessories) must be fixed directly on the discharge spigot located on the top of the unit.

A PN16 PVC spigot is supplied with the unit, which then needs to be fixed to the gate valve with the rubber connection sleeve secured to the spigot using the jubilee clips provided.

Now you can push your discharge pipe into the rubber connection sleeve and once again secure with the jubilee clips provided.

The Atlas70 (Single Phase) is designed for one lift only and the vertical lift should be made before any horizontal run.

IMPORTANT – It is recommended that there are no bends in the vertical lift, however should this be unavoidable a minimum of slow radius bends may be used.

Electrical connection
A qualified person in accordance with the Institute Of Electrical Engineers Regulations should connect the unit to the appropriate mains supply taking into account all the electrical information provided.

IMPORTANT – All pump systems must be used with an appropriate motor rated protection device.

Maintenance
The Atlas70 (Single Phase) requires minimal maintenance. It is advised that the unit is visually inspected and its functioning checked monthly. Also the unit should be rinsed through with warm water and a minimum of bleach or other appropriate cleaning product every 2–3 weeks to assist in breaking down any solids that may accumulate within the chamber.

NOTE – It is recommended that a service agreement be taken out with technically qualified company.

Health & safety
As with all site work, the danger of working with water and electricity can pose a severe threat to health if obvious and fundamental precautions are not taken. Therefore if you are in any doubt regarding the installation, please contact us.

All site work must be undertaken by qualified personnel only.

These notes are for guidance only and it is for the installer to ensure the installation is in accordance with all structural and regulatory requirements.

Our policy is one of continuous product improvement, we reserve the right to change specifications and prices without prior notice. All information is given in good faith.


Gate Valve DN80 (PN16, Cast iron)

Price: £198.00

 

Hand Membrane Pump